AquaChem Description
aquachem -
stiff diagrams, piper diagrams, radial diagrams, durov diagrams, ternary diagrams, times series graphs, schoeller plots, scatter plots, langelier-ludwig diagrams, frequency histograms, and geothermometer plots
aquachem categories: hydrogeochemical, water quality, geochemical
AquaChem Is The Most Comprehensive Software Package for Aqueous Geochemical Analysis, Plotting and Modeling
AquaChem Overview AquaChem Detailed Description
AquaChem Price
AquaChem Demo / Download
|
 |
 |
|
AquaChem Introduction
|
 |
 |
|
AquaChem
is a fully-integrated software package developed specifically for graphical and numerical analysis of geochemical data sets. AquaChem features a powerful database that can be customized and configured to include an unlimited number of attributes per sample and a built-in database of inorganic chemicals that are commonly-used for geochemical analyses, calculations and plotting.
AquaChem covers a wide range of calculations frequently used for the analysis, interpretation and comparison of aqueous geochemical data. The
analysis tools range from simple unit transformations, mixing calculations, statistics and charge balances to more complex calculations involving correlation matrices and geothermometrics. These powerful analytical
capabilities in AquaChem are complimented by a comprehensive selection of commonly-used graphical techniques to portray the chemical characteristics of geochemical and water quality data for single samples and
groups of samples. The fully customizable graphical features in AquaChem facilitate the understanding and interpretation of the many complex interactions between the groundwater and aquifer materials. AquaChem's
graphical plotting techniques include Piper, Stiff, Durov, Langelier-Ludwig, Schoeller and ternary diagrams, radial plots, scatter graphs, frequency histograms, pie charts, geothermometer plots and time series
graphs.
In addition, AquaChem features a graphical interface to the popular geochemical modeling program PHREEQC for calculating equilibrium concentrations
(or activities) of chemical species in solution and saturation indices of solid phases in equilibrium with a solution.
Once you start using AquaChem, you will see that it is truly one of the most powerful tools available for anyone dealing with the interpretation,
analysis and modeling of simple or complex aqueous geochemical data sets.
AquaChem Main Features
- Automatic unit conversions (mg/l, mol/l, mmol/l, ppm, meq, SiO2 in Si, H2Si3, etc.)
- Flexible data input methods (import from ASCII file or manual keyboard entry)
- Standard database functionality for performing queries and grouping data
- Built-in selection of common geochemical calculations and analysis methods
- Comprehensive selection of graphical techniques for representing and interpreting aqueous geochemical data
- Graphical interface to PHREEQC for geochemical modeling (PHREEQC executable included!)
AquaChem Database Features |
 |
 |
|
AquaChem Data Structure AquaChem is built around a customizable database that can be configured to include
an unlimited number of attributes per sample (e.g., chemical elements, gas concentration, isotopic composition, physical parameters, etc. Each sample in
AquaChem can be characterized according to five basic parameter groups including: (1) Header Information (Sample ID, Location, Date, Geology, etc.), (2) Physical Data
(Coordinates, sample depth, head, pH, Conductivity, etc.), (3) Cations (Ca, Mg, Na, K, etc.), (4) Anions (Cl, Br, SO4, NO3, etc.), and (5) Uncharged Compounds (Al, As,
CO2, etc.).
|
 |
 |
|
AquaChem Data Analysis
AquaChem uses the common measured values (cations and anions) for each sample to calculate additional geochemical parameters including water type,
sum of anions, sum of cations, ion balance, TDS, hardness, alkalinity, common geochemical ratios, and dissolved minerals. In addition, AquaChem also performs more advanced calculations including:
- Basic statistical calculations such as average value, standard deviation and linear correlation matrices.
- Similarity analysis to calculate a linear regression between a single sample and all other samples of the record list.
- Mixing of two samples can be performed and the results written to the database and a new sample record.
- Chemical facies can be calculated based on the elements that are present by more than 20% of the total of all elements in equivalent
concentration.
- Geothermometric calculations can be performed to estimate the original temperature at depth of sampled water.
- Upper and lower tolerance and guideline limit exceedences can be identified for every numeric parameter in the sample set.
AquaChem also produces printed reports for each record or for the entire database containing general sample information, isotope summaries, and a
list of samples. All sample records can be exported to a tab-delimited ASCII file.
AquaChem Graphical Display Features
AquaChem's powerful graphical tools utilize 15 techniques commonly used by hydrogeologists and geochemists for analyzing and interpreting aqueous
geochemical data sets for hundreds and even thousands of different samples. All text on each graphical display can be customized using a full selection of Windows true type fonts. The various graphical methods and
the display options of AquaChem are discussed below.
|
 |
 |
|
Piper Diagrams in AquaChem The Piper diagram in AquaChem plots the major ions as percentages of
milli-equivalents in two base triangles. The total cations and the total anions are set equal to 100% and the data points in the two triangles are projected onto an adjacent
grid. This plot reveals useful properties and relationships for large sample groups. The main purpose of the Piper diagram is to show clustering of data points to indicate samples that have similar compositions.
The Piper diagram in AquaChem can be used to plot all samples in the open
database or selected sample groups. In addition, the symbols representing the sample values can be customized according to shape and color. The highlighted sample points indicate samples
that are selected in the database and are also highlighted on all other open graphical displays.
|
 |
 |
|
Durov Diagrams in AquaChem The Durov diagram in AquaChem is an alternative to the Piper diagram. The Durov
diagram plots the major ions as percentages of milli-equivalents in two base triangles. The total cations and the total anions are set equal to 100% and the data
points in the two triangles are projected onto a square grid that lies perpendicular to the third axis in each triangle. This plot reveals useful properties and relationships for
large sample groups. The main purpose of the Durov diagram is to show clustering of data points to indicate samples that have similar compositions.
The Durov diagram can be used to plot all samples in the open database or selected
sample groups. In addition, the symbols representing the sample values can be customized according to shape
and color. Other options include individual multiplication factors for each selected ion to prevent data point
accumulation along a base line. The highlighted sample points indicate samples that are selected in the database and are also highlighted on all other open graphical displays.
|
 |
 |
|
Ternary Diagrams in AquaChem A ternary diagram in AquaChem is also used to identify trends and relationships
between groups of samples. However, it is generally easier to understand than Piper or Durov diagrams since it involves fewer parameters and does not involve projections
of data points onto a grid. Like the Piper diagram, the ternary diagram plots the ions as percentages of their concentration values. The ternary diagram is not limited to using only meq units.
The ternary diagram can be used to plot all samples in the open database or
selected sample groups. In addition, the symbols representing the sample values can be customized according to shape and color. Other options include individual multiplication factors for each
selected ion to prevent data point accumulation along a base line. The highlighted sample points indicate samples that are selected in the database and are also highlighted on all other open graphical displays.
|
 |
 |
|
Langelier-Ludwig Diagrams in AquaChem The Langelier-Ludwig square diagram in AquaChem is similar to the projection areas
of the Piper and Durov diagrams. Suitable groupings of cations and anions are selected and plotted as percentages of milli-equivalents. By convention, the sums of
the selected cations are plotted on the y-axis, and the sum of the selected anions are plotted on the x-axis. Each axis ranges from 0 to 50 meq%.
All major elements can be displayed in one plot with the Langelier-Ludwig diagram.
However, like the Piper and Durov diagrams, it displays relative ratios rather than absolute concentrations.
The Langelier-Ludwig diagram can be used to plot all samples in the open database or selected sample groups. In
addition, the symbols representing the sample values can be customized according to shape and color. The
highlighted sample points indicate samples that are selected in the database and are also highlighted on all other open graphical displays.
|
 |
 |
|
Scatter Plots in AquaChem The X-Y scatter plots are the most simple initial approach to the interpretation of
geochemical data. Single plots of ion relationship and parameters that show significant data can be easily created and patterns are quickly identified and easily
understood. Both normal scale and log scales are supported for the x and y axes and multiplication factors can be applied to either the x or y element. Element ratios and sums may also be included for either axes.
The scatter plot in AquaChem can be used to plot all samples in the open database
or selected sample groups. The symbols representing the sample points can be customized according to shape and color. The highlighted data points indicate specific samples that are selected
in the database and are also highlighted on all other open graphical displays.
|
 |
 |
|
Frequency Histograms in AquaChem Frequency histograms are most commonly used to check the number of populations
within a given range of measured values. This allows you to view a large number of samples without the diagram becoming too cluttered with data points. The frequency
of samples within the given ranges can be plotted according to percentages or numbers of samples.
The frequency histogram can be used to plot all samples in the open database or
selected sample groups. The range of values can be customized up to 10 or more groups and the individual samples can be identified at the associated value along the
x-axis. The highlighted data points indicate specific samples that are selected in the database and are also highlighted on all other open graphical displays.
|
 |
 |
|
Time Series Graphs in AquaChem The evolution of physical and chemical parameters for a given sampling location
is a standard technique for interpreting hydrochemical and hydrogeological processes in natural waters. AquaChem allows you to plot time-series graphs for
any numeric parameter in your database, and axes are customizable to suit your display requirements.
The time series graph plot can be used to plot all samples in the open database
or selected sample groups. The symbols representing the sample points can be customized according to shape and color. The highlighted data points indicate
specific samples that are selected in the database and are also highlighted on all other open graphical displays.
|
 |
 |
|
Geothermometer Plots in AquaChem Geothermometer plots can be used to test the quality of geothermometer estimates for a given geological and hydrogeological condition.
The Giggenbach Triangle The Giggenbach triangle is composed of three zones; (1) immature waters along the base; (2) partially equilibrated
waters in the middle; and (3) fully equilibrated waters along the upper curve. Depending on where the composition of a given sample lies within this triangle, you can estimate the extent of rock-water equilibrium
based on the concentrations of K, Mg and Na.
Log (K)-1000/T Plots The linear log (K)-1000/T plots can be used for samples from boreholes where you know the insitu temperature of the
formation. It can be used to: (i) check the usability of thermometers on a set of samples; (ii) plot the chemistry versus formation temperature; (iii) search for the geothermometer with the best fit; and (iv)
develop new chemical geothermometers for parameters which show linear behavior.
|
 |
 |
|
AquaChem Printing Results AquaChem prints all reports and graphical displays to any printer or plotter supported by Windows 95/NT. The printing utility allows you to size and arrange the
location of an unlimited number of open graphical displays on the page. This is particularly useful for comparing Stiff and radial diagrams from multiple samples or for using several different graphical displays to
interpret groups of samples in each plot. Two lines of titles can be added at the top of the page while a single line of footer information can be added at the bottom of the page.
|
 |
|
|
 |
 |
 |
|
The PHREEQC Interface
PHREEQC is a program for performing aqueous geochemical calculations and modeling including:
- Speciation and saturation-index calculations;
- Reaction-path and advective-transport calculations involving specified irreversible reactions, mixing of solutions, mineral and gas equilibria,
surface complexation reactions, and ion-exchange reactions; and
- Inverse modeling to find sets of mineral and gas mole transfers that account for composition differences between waters, within specified
compositional uncertainties.
As the name might suggest, PHREEQC is written in the C programming language and is derived from the Fortran program PHREEQE (Parkhurst et al.,
1980). PHREEQC is essentially an upgrade from the previous versions of PHREEQE since it retains all of the functionality and incorporates many improvements and new features.
|
 |
 |
|
Creating PHREEQC Input Files AquaChem provides a direct interface to PHREEQC for
creating the input files and running the simulations (WATEQ data files can also be read by PHREEQC). A full working version of PHREEQC is included with AquaChem
and can be executed directly from the interface. In order to run a geochemical simulation using PHREEQC, you must specify at least one solution to use in the simulation. The
main advantage of the AquaChem interface is that it provides a direct link between PHREEQC input and output files and the AquaChem database files. This database link
allows for instantaneous preparation of hundreds of solutions using samples from the database. Alternatively, you can also use the interface to load modeled solutions
from previous simulations or to manually prepare solutions. These features will save you an incredible amount of time and hassle when you are dealing with a large number of
samples (e.g., simultaneous speciation of many samples).
The AquaChem PHREEQC interface also provides a link between the specified solutions and other PHREEQC
operations including adding reactions to the solutions; defining mineral phases for equilibration with the solutions;
mixing solutions; adding gas phases to the solutions; specifying ion exchanges; performing 1-D transport simulations, and inverse modeling.
Once the properties of the solutions have been defined, you simply execute the PHREEQC program directly from
the AquaChem interface and the simulation calculations will take place. If additional modifications are required, AquaChem allows you to edit the PHREEQC input text file directly from the interface.
Importing PHREEQC Results AquaChem allows you to import the PHREEQC modeling output file (.pun file) into your database for creating
graphs and tables for reports and for statistically analyzing the results. When the appropriate PHREEQC
simulation output file is selected and imported, the results will be displayed in a spreadsheet. These results can be copied and pasted to other Windows applications or imported into your AquaChem database.
|
 |
 |
|
AquaChem Documentation
AquaChem is accompanied by a comprehensive user's manual containing easy-to-follow instructions and a step-by-step tutorial. Free technical support
is provided by phone, fax and e-mail.
AquaChem Requirements
Pentium with 8 MB RAM, 10 MB free disk space and Windows 95/98/2000/NT.
|
 |
 |
|
Global Enviro Software 1204 W South Jordan Prkwy #B South Jordan, Utah 84095
Phone (801) 208-3011 Toll Free (U.S.) 1-866-620-9214 Fax (801) 302-1160 E-mail info@surfacewater.com
|
|